Accessing Customer Specifications on Essae DS-450/451
⚙️ Model Compatibility: Essae DS-450, DS-450SS, DS-451, and DS-451 Flame Proof[cite: 6].
The Customer Specification menu allows technicians to adjust critical backend features like RS-232 baud rates, accumulation modes, and setpoint logic[cite: 6].
How to Enter the Specification Menu:
1. Depress the [REZERO] key and press the [←] (Digit Select) key three times[cite: 6].
2. The display will toggle between the specification number (e.g., "C10") and its current two-digit value[cite: 6].
3. Use the [←] (Digit Select) and [↑] (Digit Increment) keys to enter the required parameter value[cite: 6].
4. Press the [*] (Star) key to store the entered specification value and advance to the next parameter (e.g., C11)[cite: 6].
5. Press the [T] (Tare) key to exit the technical specification mode[cite: 6].
Important Note: The Specifications will take effect only at power on[cite: 6]. You must turn the machine OFF and ON whenever changes are made for them to activate[cite: 6].