⚙️ Model Compatibility: Essae DC-810 & DC-815 Label Scales.
The "Disp Resolution Err" message is triggered during the Power-On sequence if the scale's internal capacity and accuracy settings have been programmed incorrectly. Specifically, it occurs if the calculated ratio of (Capacity ÷ Accuracy) exceeds 15,000 divisions.
How to Fix This:
1. This is a configuration error, not a hardware failure.
2. You must enter the Settings Menu and correct the Basic Capacity and Accuracy parameters. (For example, a 15kg scale with a 1g accuracy equals 15,000 divisions, which is valid. Setting it to 0.5g would exceed the limit and cause this error).
3. If you are locked out of the menu, you must use the master override password to access the hardware configuration.